A partir de cette page vous pouvez :
Retourner au premier écran avec les dernières notices... |
Détail de l'auteur
Auteur Daddi Fadel
Documents disponibles écrits par cet auteur
Ajouter le résultat dans votre panier Affiner la rechercheCase Report: Remote Scleral Lens Fitting for High Toric Scleras in a Keratoconus Patient / Daddi Fadel in OVS : Optometry & Vision Science, vol. 100, 12 (Décembre 2023)
[article]
in OVS : Optometry & Vision Science > vol. 100, 12 (Décembre 2023)
Titre : Case Report: Remote Scleral Lens Fitting for High Toric Scleras in a Keratoconus Patient Type de document : article de périodique Auteurs : Daddi Fadel ; Cian Gildea Année de publication : 2023 Langues : Français (fre) Descripteurs (mots clés) : [Thésaurus HELB]:Paramédical:Lentille sclérale
[Thésaurus Mesh]Kératocône
[Thésaurus Mesh]Optométrie
[Thésaurus Mesh]Présentations de cas
[Thésaurus Mesh]SclèreMots-clés : sclères à tore profilométrie cornéosclérale Résumé : SIGNIFICANCE: Technology plays a crucial role in customizing scleral lenses and improving lens alignment, especially in challenging scleral shapes. In addition, remote fitting technology allows optometrists to extend their expertise globally, empowering patients to access to customized lenses without travel expenses. PURPOSE: The objective of this study was to document the difficulties encountered in fitting a scleral lens in a patient with keratoconus and pronounced scleral toricity. In addition, the study aimed to present the successful remote fitting achieved by using advanced technology. CASE REPORT: An Irish male patient diagnosed with keratoconus exhibited high scleral toricity. Generally, keratoconus eyes often exhibit significant scleral asymmetry associated with cone decentration and disease severity. Improperly aligned scleral lenses can lead to regional changes in scleral shape, lens decentration, discomfort, and visual disturbances. Indeed, previous scleral lens fits were unsuccessful because of these issues. Corneoscleral profilometry was acquired in Ireland and then used in Italy to design customized lenses, which were then delivered to the patient's optometrist in Ireland. The first lenses designed and delivered demonstrated excellent overall performance without requiring adjustments. CONCLUSIONS: This report highlights the importance of corneoscleral profilometry to increase efficiency and reduce lens reorders and chair time, and the remote fitting in overcoming barriers to accessing specialized lens fitting. Permalink : https://bibliotheque.helb-prigogine.be/opac_css/index.php?lvl=notice_display&id= [article]Exemplaires
Cote Support Localisation Section Disponibilité aucun exemplaire Fenestrated Scleral Lenses: Back to the Origins? Review of Their Benefits and Fitting Techniques / Daddi Fadel in OVS : Optometry & Vision Science, vol. 97, 09 (Septembre 2020)
[article]
in OVS : Optometry & Vision Science > vol. 97, 09 (Septembre 2020)
Titre : Fenestrated Scleral Lenses: Back to the Origins? Review of Their Benefits and Fitting Techniques Type de document : article de périodique Auteurs : Daddi Fadel ; Donald F. .Ezekiel Année de publication : 2020 Langues : Français (fre) Descripteurs (mots clés) : [Thésaurus HELB]:Optique:port de lentilles de contact
[Thésaurus HELB]:Paramédical:Lentille sclérale
[Thésaurus Mesh]HistoireRésumé : SIGNIFICANCE: This review illustrates the history of fenestrated scleral lenses, reporting personal communication from one of the present authors; describes their peculiarities and disadvantages; explains the fitting methods so far used; and recommends future fitting methods. Indications and benefits of scleral lenses are widely described in the literature. The introduction of more advanced gas-permeable materials allowed scleral lenses to spread and be available to patients worldwide. Despite the improvement of the gas-permeable scleral lens' clinical performance, complications associated with corneal hypoxia persist, especially in patients with corneal endothelial abnormalities. Fenestrated scleral lenses may solve different complications caused by hypoxia. Also, fenestrated scleral lenses may be beneficial for several issues such as handling difficulties, midday fogging, lens suction, lens instability, conjunctival compression, and alteration of IOP. There is a need and a benefit to directly comparing fenestrated scleral lenses to sealed gas-permeable scleral lenses. This topical review allows practitioners to understand the fenestration philosophy in scleral lenses, practice better, and obtain information on their indications and fitting process. Industry and patients will benefit from future advances in scleral lens designs. Permalink : https://bibliotheque.helb-prigogine.be/opac_css/index.php?lvl=notice_display&id= [article]Exemplaires
Cote Support Localisation Section Disponibilité aucun exemplaire Keratoconus: considerations, recognition and management with speciality contact lenses / Daddi Fadel in OPTOMETRY TODAY, vol. 62,05 (Octobre - novembre 2022)
[article]
in OPTOMETRY TODAY > vol. 62,05 (Octobre - novembre 2022) . - p. 80-84
Titre : Keratoconus: considerations, recognition and management with speciality contact lenses Type de document : article de périodique Auteurs : Daddi Fadel ; Greg DeNaeyer Année de publication : 2022 Article en page(s) : p. 80-84 Langues : Français (fre) Descripteurs (mots clés) : [Thésaurus Mesh]:K:Kératocône:Kératocône / anatomopathologie
[Thésaurus Mesh]:K:Kératocône:Kératocône / diagnostic
[Thésaurus Mesh]:K:Kératocône:Kératocône / thérapie
[Thésaurus Mesh]Kératocône
[Thésaurus Mesh]Lentilles de contact
[Thésaurus HELB]:Optique:lentilles scléralesMots-clés : système de lentilles piggyback Résumé : This CPD article outlines the clinical presentation of keratoconus and its management with a range of different contact lens options En ligne : https://www.aop.org.uk/ot/cpd/2022/09/30/keratoconus-considerations-recognitions [...] Permalink : https://bibliotheque.helb-prigogine.be/opac_css/index.php?lvl=notice_display&id= [article]Exemplaires
Cote Support Localisation Section Disponibilité OPT Périodique Erasme - périodiques Périodiques Disponible Scleral lens fitting: where should we start? / Langis Michaud in OPTOMETRY TODAY, Vol. 62,03 (Juin - juillet 2022)
[article]
in OPTOMETRY TODAY > Vol. 62,03 (Juin - juillet 2022) . - p. 79-84
Titre : Scleral lens fitting: where should we start? Type de document : article de périodique Auteurs : Langis Michaud ; Daddi Fadel Année de publication : 2022 Article en page(s) : p. 79-84 Langues : Français (fre) Descripteurs (mots clés) : [Thésaurus HELB]:Optique:port de lentilles de contact
[Thésaurus HELB]:Paramédical:Lentille sclérale
[Thésaurus Mesh]Éducation du patient comme sujetRésumé : This article aims to establish a step-by-step approach for practitioners who are new to scleral contact lens fitting or those looking for clinical pearls in this area En ligne : https://www.aop.org.uk/ot/cpd/2022/05/13/scleral-lens-fitting-where-should-we-st [...] Permalink : https://bibliotheque.helb-prigogine.be/opac_css/index.php?lvl=notice_display&id= [article]Exemplaires
Cote Support Localisation Section Disponibilité OPT Périodique Erasme - périodiques Périodiques Disponible